The roof anchor s shall comply with thaler design requirements.
Roof anchor spec section.
Standing seam anchor point of following types.
Osha 1910 27 and iwca 1 14 1 2001 window washing standard require that a building owner have roof anchor inspections and certifications performed on an annual basis.
Anchor and components tested for the following loads.
Section 05310 metal decking e.
Section 03400 pre cast concrete c.
Includes railing systems and roof anchor systems activar construction products group j l.
The roof anchor s shall prevent workers from reaching and falling into any open hole or off the edge of a working surface.
Restraint roof anchor s shall be designed per ansi z359 2 ansi z359 6.
Section 03300 cast in place concrete b.
Section 05100 structural metal framing d.
We specialize in roof anchor points wall anchor points rigging sleeves and davit arms sizing each product to meet your needs and specifications.
Standards with a safety factor of 2.
Minimum 6 thickness for adhesive anchor connection.
The roof anchor s shall comply with the requirements for fall arrest roof anchor s as indicated in this document.
The panels and concealed anchor clips shall be capable of supporting a 300 pound temporary concentrated load at the panel mid span in the installed condition.
Section 05400 cold formed metal framing f.
The load shall be applied over the entire panel width.
Contractor to coordinate installation of structural deck to meet requirements of roof anchor manufacturer.
Standing seam roof anchor ssra1 for individual worker capable of withstanding load as allowed by osha ansi 5 000 lbs.
Minimum concrete strength fc 2 000 psi.
Minimum 4 thickness for mechanical anchor connection.
Our strongtop permanent suspended maintenance products can be used on concrete structural steel timber and locally reinforced wood buildings.
Metal roof panel systems shall have no water leakage at a pressure differential of 6 24 psf when tested in accordance with astm e1646.