I use a wide piece of flexible flashing tape to protect the area between the subfascia and the wall.
Roof edge and stone veneer flashing.
The objective of the bedding seal is to limit water and air infi ltration.
The fl ashing should extend on to the cultured stone watertable wainscot 1 2 minimum.
The outer edge of the fl ashing should have a hemmed edge for stiffness and to protect a raw sheet metal edge from rusting.
The defect consists of the improper integration of the roof underlayment and the metal drip edge collectively referred to as the eave flashing figure 13.
Wall system adhered stone veneer over cmu backup sheathing z channels 03 080 0201.
To maintain the weather resistance of the extenor wall on which the stone is installed a corrosion resistance flashing and a means of drainage should be installed at all wall penetrations and terminations of the stone veneer.
Flashing a stone veneer chimney.
However the lintels are not continuous.
A flexible flashing can be formed around the bolt heads see figure 5.
Cmu stone on both.
Stone veneer at grade.
Flashing type and locations shall be in accordance with the local building code.
There is usually a lintel or shelf angle that supports the masonry veneer above the window.
Wall system adhered stone veneer over steel studs backup rigid insulation w taped joints.
Wall system adhered stone veneer over steel studs backup fiberglass insulation 03 080 0203.
Before beginning stone veneer application install flashing at all through wall penetrations and at terminations of adhered concrete masonry veneer installat.
When flashings are specified to be terminated within the face of the masonry veneer and not daylighted to the exterior water may flow off of the edge of the flashing and be retained within the wall.
All install flashing guide pdfs zip download dwg files zip download dxf files zip individual flashing guides.
C bedding seal under gsm flashing.
Many times drips are opposed by the designer for aesthetic reasons.
Above the roof sheathing.
Window and door heads flashings at window heads are very similar to those at shelf angles.
I cut the tape so that it laps onto the housewrap above and 3 in.
If the roof underlayment does not lap properly over the metal drip edge water is potentially allowed to penetrate to the roof deck fascia and sub fascia areas which typically include.
The shingles get step flashed to the 2x and the the 2x gets a zbend counter flashing that gets tucked under the house wrap before the felt or mesh is installed.