The required roof snow loads for minnesota aren t clearly spelled out anywhere but the numbers can be found by using table r301 2 1 of the minnesota administrative rules.
Roof live load in minnesota.
F the ground snow loads to be used in determining the design snow loads for buildings and other structures are given in minnesota rules part 1303 1700 ground snow load to verify by county.
0 7 x 60 psf 42 psf below line.
Frost depth map minnesota rules 1303 1600.
D dead load l live load l r live roof load w wind load s snow load e earthquake load r rainwater load or ice water load t effect of material temperature h hydraulic loads from soil f hydraulic loads from fluids.
This issue of live load vs.
The north zone middle zone and the south zone are identified on the roof load zone map above.
This downward imposed load on the home is also known as the snow load.
Snow load map ground load and roof load map per minnesota rules 1303 1700.
Roof loads are a downward vertical force on the home.
In areas of the state outside of certified local government jurisdictions the design snow load shall be based on the ground snow loads developed in snow loads for structural design in montana authored by f f.
The minimum design roof snow load.
The north zone design live load equates to 40 pounds per square foot.
Roof load live load design is affected by the shape of the roof whether it is flat curved or pitched.
0 7 x pg ground snow load pf roof snow load roof snow load examples.
However a south roof load zone home cannot be installed in either a middle or north roof load zone.
Victor staley a building official in the town of brewster mass responds.
This table says that.
The load increases with the use of heavier roofing material.
Soil classification and bearing table.
0 7 x 50 psf 35 psf.
The dead load of a typical asphalt shingled wood framed roof is about 15 pounds per square foot.
Psf pounds per square foot.
Round footing sizing table.
Schilke civil agricultural engineering montana state university august 1989.
The roof snow load is a uniform load on the horizontal projection of the roof.
To calculate roof snow load per residential building code.
Ground snow load might seem somewhat confusing until you read the basic premise that is identified in irc section r301 6 which states.
Since the late 1960s and early 1970s roof construction for residential structures has consisted of pre manufactured engineered roof trusses.
Egress windows for manufactured homes jan.
Arch 331 note set 13 1 s2014abn 2.
G see minnesota rules chapter 1335 flood proofing regulations.
Square footing sizing table.