Thru roof mast type overhead service combination entrance type 120 240 volt single phase 100 amp 200 amp 300 amp.
Roof mounted service entry head.
Retaining walls of 4 feet 1 2 m or less in height level backfill.
Canopies or awnings extending not more than 54 inches 1 4 m from the exterior wall of the building.
And for a more detailed exploration of the requirements as the service wires cross above a roof see our blog post what is the minimum clearance of overhead electric service drop wires above a house roof.
2 inch for 2 conductors 100 amp loop.
Service entrance se roof flashing model 60820 7 63 7 63.
Mfr 626 view product.
The service head and service point when the service drop reaches the house it connects to an assembly called the service head also know as the service mast or masthead.
Raco rigid imc or emt 2 in.
Service entrance mast kit 2 in with service entrance cap roof flashing wire holder and straps.
2 inch for 4 0 conductors 200 amp loop.
This connection point is called the service point and in many cases represents the dividing line between the utility and the customer.
Service entrance head model 2414 74 29 carton 74 29 carton.
Mfr mk200wh view product.
A disconnecting means must be provided for all mobile manufactured home ex.
Typically a service head consists of a rigid steel conduit like a big pipe that runs up through the roof or along an exterior wall and is topped with a shell like fitting called a weatherhead or weather cap.
For overhead service weather head must be a minimum of three feet above the roof.
Wire fences and other fences not over 6 feet 1 8 m in height.
For underground service the poured footing must be notched out for the conduit.
Service entrance equipment the service entrance conductors raceway and fittings or service entrance cable and fittings which are installed on the customer s premises to connect the electric service to the wiring inside the building.
Service raceway the conduit containing the service entrance conductors.
Roof flashing 2 1 2 in.
Set your store to see local availability add to cart.
Service entrance head 5 pack model 2408 72 57 carton 72 57 carton free delivery.
And by the way if anyone is paying attention the service mast shown at the top of the page is a 4 wire for three phase service which is.
Service entrance se midget 1 hole cable straps 50 pack model 26214 2 94 bag 2 94 bag.
Set your store to see local availability add to cart.
Dca or when service is located other than on the exterior wall of the building served 30 feet maximum.
Free delivery with 45 order.
The service drop typically connects to the house at the top of a vertical pipe called a masthead or weatherhead.
Consumer to provide and have installed.
3 inch for 350 conductors 300 amp loop.
Platforms walks and driveways.
In roof area used as storage sheds playhouses and similar uses.