Cbi has been performing tdi windstorm inspections in the windstorm areas since 1991.
Roof nail l2006 irc.
Name of legally binding document.
In determining nail length consider the number of layers of shingles shingle thickness es underlayment and flashing eaves sidewall and valley etc.
Windstorm roofing requirements 2006 irc 1 windstorm roofing requirements 2006 irc coastal building inspections and engineering cbi is an engineering and inspection company located in alvin texas.
26 rim joist or blocking to sill plate toe nail 8d 2 x 0 113 6 o c.
27 1 6 subfloor or less to each joist face nail 24 27 2 8d 2 x 0 113 2 staples 1.
Typical wood frame home with osb wall and roof sheathing.
Today we are going to delve in the final building walls floors roofing finishes sections of the code in particular the biggest changes we see between the 2009 irc and the popular 2003 2006 irc.
If the deck sheathing is less than thick use nails long enough to penetrate the roof deck sheathing and extend at least 1 8 beyond the lower side of the roof deck.
Yesterday we looked at the first four chapters of the 2009 irc as it is part of alabama s new building energy code that goes into effect in less than a week.
The international code council icc is a non profit organization dedicated to developing model codes and standards used in the design build and compliance process.
International residential code name of standards organization.
I understand that the hvhz is different i am asking about everywhere else in the state.
For example according to the table 7 16 osb oriented strand board wall sheathing may be fastened with 6d common box or casing nails or 1 3 4 16 gage staples at 6 on center at the panel edges and 12 on center in the field special conditions apply for shear walls.
The international codes i codes are the widely accepted comprehensive set of model codes used in the us and abroad to help ensure the engineering of safe sustainable affordable and resilient structures.
Similarly 19 32 osb roof sheathing would be 8d.
25 rim joist to top plate toe nail roof applications also 8d 2 x 0 113 6 o c.
My understanding is that after 2008 all roof decks had to be re nailed when a new roof is installed.
Where the roof sheathing is less than 3 4 inch 19 mm thick the.
Some homes being built after 2002 the builders started to use the new nailing and some ahj required new nailing on new builds.
Astm d 3161 normal application of four nails per shingle or manufacture s specification.
Addeddate 2012 07 31 18 53 03 identifier gov law icc irc 2006 identifier ark ark 13960 t30301r3c ocr abbyy finereader 8 0 ppi 300.