And vented or unvented attics that are insulated above the roof deck with rigid foam.
Roof deck insulation foam.
Most unvented attics incorporate spray polyurethane foam spf on the underside of the roof deck and attic walls.
A sealed and insulated roof deck can t dry inward to the attic if the roofing happens to let water.
Shown to withstand delamination deterioration warping and jobsite damage more effectively than other roofing membrane substrates such as paper faced gypsum board fiber board and perlite insulation.
Also the higher the indoor humidity the more insulation is needed to avoid condensation.
Gaco is a best in class provider of silicone roof coating systems waterproofing and insulation solutions for commercial and residential buildings.
Rigid foam board is just above the roof deck or an exterior insulation option.
It typically has 3 variations.
Spray foam insulation applied on the underside of the roof deck in cold climate commercial buildings allows for a significant reduction in condensation potential particularly compared to interior air permeable batt systems.
Generally more insulation is needed for condensation control in colder climates.
Bare foam board one sided sheathing board or double sided which is also reference as structural insulated panels.
An excellent fire barrier densdeck roof boards feature a noncombustible core and inorganic surface that offer greater fire protection than other conventional commercial roofing products when applied over combustible roof decks and steel decks.
It s not coming from above the roof and it s not some new moisture source resulting from the spray foam.
Unvented attics that are insulated on the underside of the roof deck with blown spray foam.
The later is used in new construction as the interior board serves as an inner wall.
This construction approach was first used in the 1970s and it has been implemented much more widely since it was first included in the international code council s icc model building code in 2007 irc section 806 4.
But foam also traps moisture in the roof in case of a leak.
With enough closed cell spray foam under the deck or enough rigid above the deck interior moist air can t condense if the there is no condensation you don t need drying thus no need to vent.
The amount of closed cell spray foam or rigid insulation is somewhere between 20 to 50 of the r value of the overall cavity insulation depending on your climate zone.
High efficiency attic insulation helps provide added thermal protection lessens wasted energy and increases enhanced comfort and quiet.
As air impermeable insulation spray foam insulation can be used in such applications.
The ratio of insulation above the roof deck or air permeable insulation below the roof deck is a matter of climate and interior conditions.